Horno KF | Kyoto Electronics Manufacturing |
ADP-344 |
Heat Extractor for Sugar Samples. The ideal solution sugary samples: This mantel heater for volumetric Karl Fischer titration cells ensures the complete extraction of the moisture content of samples like chocolates, caramels and other samples containing sugars. |
Más información |
Horno KF | Kyoto Electronics Manufacturing |
ADP-512 |
Evaporator for Ores. This oven is designed to use with KEM Karl Fischer moisture titrator for measurement of combined water in iron ores according to JIS M8211 Iron Ores – Method for Determination of Combined Water Content. |
Más información |
Horno KF | Kyoto Electronics Manufacturing |
ADP-512S |
Evaporator for High Temperature. This oven evaporates moisture in ores, metallic powder, ceramics and other solids and powder materials by high heat (maximum: 1000℃) for measurement of water content connected to Karl Fischer moisture titrator. |
Más información |
Horno KF | Kyoto Electronics Manufacturing |
ADP-513 |
Evaporator for Oil Samples. This unit evaporates moisture of samples dissolved in a heated base oil. This unit is primarily used for moisture measurements in lubricant oil, grease, tar products, paints and other viscous liquids. |
Más información |
Horno KF | Kyoto Electronics Manufacturing |
ADP-611 |
Drying oven for moisture measurement on chip, particulate or powder samples such as plastic pellets. Maximum set temperature: 300℃. |
Más información |
Valorador KF coulométrico | ECH |
AQUA 40.00 Vario / AQUA 40.00 Vario PLUS |
Water determination with headspace method (up to 300°C); according to standard ASTM D 6304; system with closed circuit of the extraction gas (no external carrier gas necessary); for solid, pasty, liquid samples; formula generator for individual result output; manual version and PLUS version with autosampler (can be retrofitted); suitable furnace inserts/sample plates depending on vial size; connection for balance; can be coupled with HT 1300 high-temperature oven (300 to 1300°C); universal reagent exchange module SWOP Box can be connected. |
Más información |
Valorador KF coulométrico | ECH |
Aquamax KF Online |
Continuous water determination in oils; system with closed circuit of the extraction gas (no external carrier gas necessary); no oils in the titration cell; minimised side reactions due to additives and sulphur due to heating procedure; direct coupling to the process to be monitored; typical measuring time 2 to 5 min; heating temperature: 35 to 250°C; measuring range: > 0.1 ppm. |
Más información |
Valorador KF coulométrico | ECH |
Aquamax KF Plus |
Water determination in liquids by direct injection into the titration cell; complies with ASTM, API, BS, DIN, EI/IP, ISO standards; optionally with transport case; easy operation; measuring range 1 ppm / 100%; battery operation; integrated printer; small footprint. |
Más información |
Valorador KF coulométrico | ECH |
Aquamax KF PRO LPG |
Water determination in gases and LPG according to ASTM D 7995; titration system combined with automatic dosing module; completely automated measuring procedure incl. purging steps; for liquefied and gaseous samples; sulphur trap prevents side reactions caused by sulphides/H2S/mercaptans; no separate purging gas necessary; up to 250 measurements in 48 h; measuring range 1 ppm to 10%; typical measuring time 5 to 15 min; automated sample feeding of liquefied gases via optional LPG Selection Box. |
Más información |
Valorador KF coulométrico | ECH |
Aquamax KF PRO Oil |
Karl Fischer titration combined with gas extraction furnace for water determination in oils according to ASTM D 6304; system with closed circuit of the extraction gas (no external carrier gas necessary); no oils in the titration cell; manual version and AUTOMATIC version with autosampler for 200 syringes; minimised side reactions due to additives and sulphur due to heating procedure; no blank value; connection for balance; typical measuring time 2 to 5 min; heating temperature: 35 to 250°C; measuring range: 0.0001 to 100%. |